Portable grounding devices manufactured according to standards DIN, VDE 0683 and actual normative-technical documentation. According to customer’s part list (but observing standard’s demands) portable-grounding devices can be manufactured with quantity of phases different from standard quantity and with the length of grounding short-circuiting flexible conductors different from standard values. Phase’s clamps can be connected by…
Grounding device ZPL are intended for worker’s protection from electric shock on the de-energizing parts of high voltage lines in the case of mistaken voltage feed to this part or appearance of induced voltage. The main parameters of grounding devices: Name of parameter Marking of grounding device ZPL-1B 1П, 1В ZPL-10B 10П, 10В ZPL- 35-1…
Grounding devices ZPP are intended for protection workers on the disconnecting parts of switchgears from electric shock in the case of mistaken feed of voltage to this part. The main parameters of grounding device: Name of parameter ZPP-1 ZPP-15 ZPP-35 ZPP-110 ZPP-220 Nominal voltage of electrical installations, kV 1 15 35 110 220 Length of…
Grounding device ZPMZ 6-10 is intended for grounding of phase conductors on the de-energized parts of power line with voltage to 10 kV directly from the ground’s surface. Main parameters of grounding device: Name of parameter Value of parameter Nominal voltage of electrical installations, kV 10 Length of rod’s insulating part, m, not less 0.7…
Grounding device ZNL is intended for special disconnection of air power lines by means of throw on the conductors of power line flexible non-insulated conductor and creation short circuit between conductors of power line and grounding conductor connected with the ground. The main parameters of grounding device: Name of parameter Value of parameter Nominal…
Grounding device ZPMZ is intended for worker’s protection from electric shock on the disconnecting parts of high voltage lines in the case of mistaken voltage feed to this part or appearance of induced voltage. The main parameters of grounding device: Name of parameter Marking of grounding device ZPMZ-110- 220 ZPMZ-330- 500 ZPMZ-750 ZPMZ-1150 Nominal voltage…
Grounding device is intended for worker’s protection from induced electric current shock by means of overhead ground-wire cable’s for power lines 110-1150 kV and also can be splitting. Grounding device consists of: • Insulating rod; • Clamp and cramp for fixing grounding device on the overhead ground-wire cable; • Flexible grounding conductor in transparent polymer…
Apparatus PPK is intended for testing of presence or absence of voltage in repairing cable 10 kV or 35 kV by its puncture along diameter with shorting between cores of all phases and to the ground. The main parameters of apparatus: Name of parameter Marking of article PPK-10 PPK-35 Nominal voltage of puncturing cable, kV…
Grounding device ZPMZ-K is intended for worker’s protection from electric shock on the disconnecting parts of the contact network of electric railways (in the case of mistaken feed of voltage or appearance on the part of contact network induced voltage) by means of shorting between elements of contact network hanger and the main way (under…