Contact-type voltage detectors “Ekitest”

Low voltage detector’s “Ekitest” are intended for detecting presence of voltage of direct and alternating current at the electrical installations with voltage up to 1000 V. Name of parameters Value of parameters Values of controlling voltage, V Up to 1000 Voltage of phase’s induction, V, not more 90 Charging duration from alternate current supply line…

More >>
Contact-type voltage detectors “Ekitest”

Low voltage detector’s “Ekitest” are intended for detecting presence of voltage of direct and alternating current at the electrical installations with voltage up to 1000 V. Name of parameters Value of parameters Values of controlling voltage, V Up to 1000 Voltage of phase’s induction, V, not more 90 Charging duration from alternate current supply line…

More >>
Contact type voltage detectors with combined indication “Ekivolta 6-20M”, “Ekivolta 6-20K”, “Ekivolta 20-35”, “Ekivolta 20-35K” without built-in power source.

Detectors are intended for detecting presence or absence of voltage in electrical installation of alternating current with frequency 50 Hz and voltage from 6 to 20 kV inclusive and from 20 to 35 kV inclusive. The main parameters of detectors: Name of parameters Name of voltage detectors “Ekivolta 6-20M” “Ekivolta 6-20K” “Ekivolta 20-35” “Ekivolta 20-35K”…

More >>
Contact-type voltage detector with combined indication without built-in power sours “Ekivolta 6-10KU”

Voltage detector “Ekivolta 6-10KU” is used as the main electric protective means for determining voltage’s presence or absence in closed switchgears of alternating current with voltage from 6 to 10 kV inclusive. The main parameters of the detector: Operating voltage, kV from 6 to 10 (inclusive) Type of indication combined (light – the main, Acoustic…

More >>
Contact-type voltage detector with combined indication without built-in power source “Ekivolta 6-10KUD”

Voltage detector “Ekivolta 6-10KUD” is used as the main electric protective means for determining voltage’s presence or absence on the air power lines with voltage from 6 to 10 kV inclusive without rising on the power support from the ground. Operating voltage, kV from 6 to 10 (inclusive) Type of indication combined (light – the…

More >>
Contact type voltage detectors with combined indication “Ekivolta 35-110”, “Ekivolta 35-110K”, “Ekivolta 35-220”, “Ekivolta 35-220К” without built-in power source

Detectors are intended for detecting presence or absence of voltage in electrical installation of alternating current with frequency 50 Hz and voltage from 35 to 220 kV inclusive. The main parameters of detectors: Name of parameters Name of voltage detectors “Ekivolta 35-110” “Ekivolta 35-110K” “Ekivolta 35-220” “Ekivolta 35-220K” Nominal voltage of electrical installation, kV, not…

More >>